- Plug-and-pump installation
Plug in without worrying about overheating. Built-in contactor and thermal sensors protects the motor from overheating.
Pumps with a built-in AquaTronic unit will electronically adjust for incorrect phase order, ensuring correct impeller rotation. - Reliable and trouble-free operation
A double outer casing and good heat convection allows continuous operation at low water levels – or dry running – without motor damage. The pump design, robust construction and premium materials ensure high wear resistance. - Serviceability
The modular design of the pump range saves cost by ensuring maximum pump availability with a smaller spare parts inventory.
The condition of a pump with a built-in AquaTronic unit can rapidly be checked without disassembly, using its service software. - Saves energy and the environment
The high-efficiency motor and hydraulics are combined with low friction bearings to reduce power losses. You achieve low total energy costs and minimize your carbon footprint. Environmentally safe white oil is used in the oil casing for easy inspection of seal conditions.
- XJC 110 ND medium head 3-phas
- XJC 110 ND AT* medium head 3-phase
- XJC 110 HD high head 3-phase
- XJC 110 HD AT* high head 3-phase
Weight: 80 kg (176 lb)
*AquaTronic: Built in electronic pump control.
AquaTronic option
The AquaTronic unit (AT) replaces the built-in contactor in the basic pump configurations and ensures that the motor always rotates correctly, no matter how the phases are connected. Key benefits of the AquaTronic unit include:
- Correction of motor rotation if phases are improperly connected
- Run mode (no panel needed)
- Integrated start equipment (direct or soft start depending on pump model)
- Motor protection against high temperature, high amperage and missing phase
- Anti-clog function
If the pump is also equipped with an optional level sensor, AquaTronic provides:
- Precise level control
- Protection against dry running
- Energy save mode (energy is saved through stopping at dry run and starting by level sensor)
AquaTronic service diagnostic program
Connecting a PC to the AquaTronic unit via USB cable provides access to the service diagnostic program, which offers:
Pump status data, pump operating history, pump failure history, pump service/maintenance history, digital manual and spare part documentation
AquaPlug and AquaTronic control panel
AquaPlug and AquaTronic control panel are options that combine with AquaTronic to provide additional alarm and start/stop functions, as well as indications for important parameters.
Starting method and motor protection
XJC 110 AT: Soft start (400 V 50 Hz / 380-460 V 60 Hz) is built in with the AquaTronic unit, where three thyristors reduces start current to three times the nominal current. Here two relays ensure correct motor rotation. The AquaTronic unit monitors motor temperature, by use of NTC thermistors built into stator windings, and stops the motor at high temperature. It will also stop the motor at high amperage or if a phase is missing.
XJC 110: Direct on line start with built in contactor. Pumps to be used with VFD or 1,000 V must have terminal block instead of contactor. Thermal switches (140°C / 284°F, ±5) built into the stator windings are connected to the contactor and stop the pump at high temperature.
Discharge connections
3” (standard HD), 4” (standard ND), 6” hose connections |
3”, 4”, 6" G/B.S.P. threaded connections |
3”, 4”, 6" NPT threaded connections |
Electric submersible pump | XJC 110 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 7.5 x 22 mm |
Max number of starts | 30/hour |
Motor rating P2 | 11.8 kW |
Speed | 2,920 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | XJC 110 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 7.5 x 22 mm |
Max number of starts | 30/hour |
Motor rating P2 | 13.5 kW |
Speed | 3,500 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | XJC 110 |
Maximum submergence | 65 ft |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 104ºF |
Max. media density | 0.0397 lb/inch3 |
pH of the pumped medium | 5-8 |
Strainer hole | 5/16” x 7/8” |
Max number of starts | 30/hour |
Motor rating P2 | 18 Hp |
Speed | 3,500 rpm |
Power cable | 65 ft type AWG |
Brochures
Data sheets
Accessories list
Manual
-
Troubleshooting with XJ service data kit (pdf)Languages: EN
Assembly drawings
Spare parts list
-
Spare Parts XJ/XJC 50-110 (Multilingual) (pdf)Languages: EN
-
Repair Kit - XJ/XJC/XJS 50-110 (pdf)Languages: EN
-
Dewatering in constructionFrom roads and bridges to tunnels and dams, construction sites are difficult places to work. Construction site managers need solid economic reasons for purchasing equipment. Our dewatering pumps provide them.