Current Issue: 1/2012

Simulation of the flow in a pump sump


Pump sump with a vertical pump: view of the water surface (green) and the streamlines, colored by velocity (increasing velocity: blue, green, red).

Prediction of the dynamic forces acting on a shaft

By means of flow simulation, engineers from Sulzer Pumps and Sulzer Innotec have been able to show that a modified pump sump geometry can lead to significantly smoother and uniform inflow at the pump inlet. The radial forces acting on the shaft can therefore be reduced and mainly centered around the zero point, allowing a significant increase in the lifetime of the bearings.

Sulzer Technical Review, Issue 03/2011
Author(s): Felix A. Muggli, Susanne Krüger
Division: Sulzer Pumps, Sulzer Innotec

Download as PDF file (pdf, 0.65 MB)